C02872
Parameter | Name:
C02872 | PLI without motion: Adaptation of time duration
From version 11.00.00
Setting range
(min. value | unit | max. value)
-10
Subcodes
C02872/1
Read access
C02873
Parameter | Name:
C02873 | PLI without motion: Ident. el. rotor displ. angle
From version 11.00.00
Display range
(min. value | unit | max. value)
0
Subcodes
C02873/1
Read access
C02874
Parameter | Name:
C02874 | PLI without motion
From version 11.00.00
Setting range
(min. hex value | max. hex value)
0x0000
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Subcodes
C02874/1
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Lenze setting
0
Write access
CINH
PLC STOP
°
Write access
CINH
PLC STOP
= bit set)
for SLPSM with controller enable
for SC PSM with mains on
for SC PSM with controller enable
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Lenze setting
1
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Pole position identification without motion
10
Info
PLI without motion: Adaptation of time duration
No transfer
COM
MOT
Scaling factor: 1
Pole position identification without motion
360
Info
PLI without motion: Ident. el. rotor displ. angle
No transfer
COM
MOT
Scaling factor: 1
Pole position identification without motion
0xFFFF
Info
PLI without motion
No transfer
COM
MOT
Parameter reference
Parameter list | C02872
Data type: INTEGER_8
Index: 21703
= 54C7
d
h
Data type: INTEGER_16
Index: 21702
= 54C6
d
h
Data type: UNSIGNED_16
Index: 21701
= 54C5
d
h