8400 HighLine C | Reference manual
Motor control (MCTRL)
Motor selection/Motor data
Accepting the default values of the motor
If a motor is selected from the motor catalogue at a later time, the Use motor's default
values dialog box is displayed afterwards which includes all motor data of the selected
motor. Please select here which of the default values are to be copied to the controller:
The listed motor parameters are already optimally preset for the selected Lenze motor.
An adaptation is not required.
The "plant parameter" term comprises all parameters that result from the combination
of motor and load. These characterise the transfer behaviour of the entire controlled
system.
– The plant parameters depend on the application in which the controller and motor
are used.
– When a Lenze motor is selected in the »Engineer«, plant parameters are suggested
for this motor for a load-free operation.
Tip!
If a third party manufacturer's motor is used, select a Lenze motor from the motor
catalogue first which is similar in terms of current, voltage and speed rating. Adapt
the preselected motor data exactly to the real motor afterwards.
136
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
L
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011