Parameter list | C00517
C00517
Parameter | Name:
C00517 | User menu
When a system is installed, parameters must be changed time and again until the system runs satisfactorily. The
user menu of a device serves to create a selection of frequently used parameters to be able to access and change
these parameters quickly.
• Format: <code number>,<subcode number>
• If "0.000" is set, no entry will be displayed in the user menu.
Setting range
(min. value | unit | max. value)
0.000
Subcodes
C00517/1
C00517/2
C00517/3
C00517/4
C00517/5
C00517/6
C00517/7
C00517/8
C00517/9
C00517/10
C00517/11
C00517/12
C00517/13
C00517/14
C00517/15
C00517/16
C00517/17
C00517/18
C00517/19
C00517/20
C00517/21
C00517/22
C00517/23
C00517/24
C00517/25
C00517/26
C00517/27
C00517/28
C00517/29
C00517/30
C00517/31
C00517/32
Read access
804
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Lenze setting
51.000
53.000
54.000
61.000
137.000
166.003
0.000
11.000
39.001
39.002
12.000
13.000
15.000
16.000
22.000
120.000
87.000
99.000
200.000
0.000
0.000
0.000
0.000
105.000
173.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
Write access
CINH
PLC STOP
L
16000.000
Info
C00051: Display of actual speed value
C00053: Display of DC-bus voltage
C00054: Display of motor current
C00061: Display of heatsink temperature
C00137: Display of device status
C00166/3: Display of current error message
User menu: Entry 7
C00011: Reference speed
C00039/1: Festsollwert 1
C00039/2: Festsollwert 2
C00012: Accel. time - main setpoint
C00013: Decel. time - main setpoint
C00015: V/f base frequency
C00016: Vmin boost
C00022: Imax in motor mode
C00120: Setting of motor overload (I
C00087: Rated motor speed
C00099: Display of firmware version
C00200: Display of firmware product type
User menu: Entry 20
User menu: Entry 21
User menu: Entry 22
User menu: Entry 23
C00105: Decel. time - quick stop
C00173: Mains voltage
User menu: Entry 26
User menu: Entry 27
User menu: Entry 28
User menu: Entry 29
User menu: Entry 30
User menu: Entry 31
User menu: Entry 32
No transfer
COM
MOT
Scaling factor: 1000
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: INTEGER_32
Index: 24058
= 5DFA