Diagnostics & error management
Error messages of the operating system
oC12: I2xt overload - brake resistor [xx.0123.00065]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Too frequent and too long braking processes.
oC11: Clamp operation active [xx.0123.00071]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
The device indicates that the "CLAMP" overcurrent
limitation has been activated.
• A permanent clamp operation causes an overload
disconnection.
Id5: Pole position identification error [xx.0123.00074]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
The pole position identification has not been completed
successfully.
oC13: Maximum current for Fch exceeded [xx.0123.00090]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
The device has detected a motor current which exceeds
the maximum current limit at permanent switching
frequency of the inverter.
• If a permanent switching frequency inverter is set, a
certain limit arises for the maximum current,
depending on the setting. If this current limit is
exceeded due to a load impulse or overload, an error
message is displayed.
ot2: Speed controller output limited [xx.0123.00093]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
The output of the speed controller has reached the
internal limit value. In this state, the speed controller is
not able anymore to correct the system deviation.
• Only with "Closed loop" operation or vector control
(SLVC).
594
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
L
4: WarningLocked
5: Warning
6: Information
Remedy
Check drive dimensioning.
4: WarningLocked
5: Warning
6: Information
Remedy
Reduce setpoint generation dynamics or motor load.
Setting:
C00643/1
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
Check parameter setting of the pole position
identification.
4: WarningLocked
5: Warning
6: Information
Remedy
• Observe the maximum current setting depending on
the set switching frequency of the inverter.
• Reduce the required load or setting of the dynamic
switching frequency if necessary.
Setting:
C00567
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
• Observe load requirements.
• Correct dimensioning or reduce setpoint generation
dynamics if necessary.