8400 HighLine C | Reference manual
Parameter reference
Parameter list | C01227
C01227
Parameter | Name:
C01227 | MCK: Ref. positions
Positions for determining the zero position of the reference measuring system
Setting range
(min. value | unit | max. value)
-214748.3647
Subcodes
C01227/1
C01227/2
Read access
C01228
Parameter | Name:
C01228 | MCK: Ref. sequence profile
Number of the sequence profile the absolute position of which will be approached after homing.
Setting range
(min. value | unit | max. value)
0
Read access
C01229
Parameter | Name:
C01229 | MCK: Position limiting values
Software limit position for limiting the valid traversing range
• The error response to leaving the valid traversing range can be parameterised in
Note:
For limiting the traversing range by means of software limit positions, the home position must be known and the
positive software limit position must be higher than the negative software limit position!
Setting range
(min. value | unit | max. value)
-214748.3647
Subcodes
C01229/1
C01229/2
Read access
944
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
unit
214748.3647
Lenze setting
0.0000 unit
0.0000 unit
Write access
CINH
PLC STOP
Write access
CINH
PLC STOP
units
214748.3647
Lenze setting
0.0000 units
0.0000 units
Write access
CINH
PLC STOP
L
Info
MCK: Ref. offset reference degree
• Relative traverse path by which the drive traverses
after detection of the reference initiator.
MCK: Ref. home position
• Position with which setpoint and actual position are
loaded after completion of homing.
No transfer
COM
MOT
Scaling factor: 10000
Lenze setting
15 0
No transfer
COM
MOT
Scaling factor: 1
Info
MCK: Positive SW limit position
(positive travel range limit)
MCK: Negative SW limit position
(negative travel range limit)
No transfer
COM
MOT
Scaling factor: 10000
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: INTEGER_32
Index: 23348
= 5B34
d
h
Homing
Data type: UNSIGNED_8
Index: 23347
= 5B33
d
h
Homing
Data type: INTEGER_32
Index: 23346
= 5B32
d
h
C00595/3
and C00595/4.
Limit position monitoring