8400 HighLine C | Reference manual
Diagnostics & error management
Error messages of the operating system
Cl01: Module missing/incompatible [xx.0140.00013]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
The optional communication module has been removed
or there is a connection problem or incompatibility with
the standard device.
PS01: No memory module [xx.0144.00001]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Memory module is either not available or not snapped
into place correctly.
PS02: Par. set invalid [xx.0144.00002]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
The parameter set saved to the memory module is
invalid because it has not been saved completely.
• This can be due to voltage failure or caused by
removing the memory module while saving the
parameter set.
PS03: Par. set device invalid [xx.0144.00003]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
The parameter set saved to the memory module is
incompatible to the standard device.
• An incompatibility of the parameter set is caused e.g.
when the memory module of an 8400 HighLine is
plugged into an 8400 StateLine or the parameter set
in the memory module has a higher version than
expected by the standard device.
600
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
L
Setting:
C01501/2
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
• Check connection between the communication
module and standard device.
• Check if the module is plugged in correctly.
• In case of an incompatibility, either the module or the
software of the standard device is out of date. In this
case, please contact Lenze.
4: WarningLocked
5: Warning
6: Information
Remedy
• If a memory module has been provided: Plug the
memory module into the slot of the standard device
intended for this purpose.
• If a memory module has been provided: Check if the
memory module has been plugged-in correctly.
4: WarningLocked
5: Warning
6: Information
Remedy
Ensure voltage supply during the storage process and
that the module remains plugged into the slot.
4: WarningLocked
5: Warning
6: Information
Remedy
When the memory modules are exchanged, observe the
downward compatibility:
• OK: StateLine V2.0 to StateLine V3.0
• OK: StateLine V2.0 to HighLine V2.0
• Not OK: HighLine Vx.x to StateLine Vx.x
• Not OK: StateLine V3.0 to StateLine < V3.0