C00585
Parameter | Name:
C00585 | Resp. to motor overtemp. PTC
Response to motor overtemperature
• The motor temperature is measured by means of a PTC thermistor at terminal X106.
Selection list
(Lenze setting printed in bold)
Read access
C00586
Parameter | Name:
C00586 | Resp. to encoder open circuit HTL
Response to encoder feedback system failure or encoder feedback system track failure due to open circuit
Selection list
(Lenze setting printed in bold)
Read access
C00588
Parameter | Name:
C00588 | Resp. to max. speed at switching freq.
Response if the maximum speed for the set inverter switching frequency is reached (C00018)
Selection list
(Lenze setting printed in bold)
Read access
C00590
Parameter | Name:
C00590 | Resp. to switching frequency red.
Response to reduction of the inverter switching frequency (C00018)
Selection list
(Lenze setting printed in bold)
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 No Reaction
1 Fault
5 Warning
Write access
CINH
PLC STOP
0 No Reaction
1 Fault
5 Warning
Write access
CINH
PLC STOP
0 No Reaction
1 Fault
5 Warning
Write access
CINH
PLC STOP
0 No Reaction
1 Fault
5 Warning
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
No transfer
COM
MOT
Scaling factor: 1
No transfer
COM
MOT
Scaling factor: 1
No transfer
COM
MOT
Scaling factor: 1
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00585
Data type: UNSIGNED_8
Index: 23990
= 5DB6
d
h
Data type: UNSIGNED_8
Index: 23989
= 5DB5
d
h
Data type: UNSIGNED_8
Index: 23987
= 5DB3
d
h
Data type: UNSIGNED_8
Index: 23985
= 5DB1
d
h
809