C00950
Parameter | Name:
C00950 | L_Interpolator_1: Activation FB functions
From version 04.00.00
The
L_Interpolator_1
Selection list
Subcodes
C00950/1
C00950/2
C00950/3
Read access
C00951
Parameter | Name:
C00951 | L_Interpolator_1: No. of interpolation steps
From version 04.00.00
The
L_Interpolator_1
Setting range
(min. value | unit | max. value)
0
Read access
C00952
Parameter | Name:
C00952 | L_Interpolator_1: Limit value - error cycles
From version 04.00.00
The
L_Interpolator_1
Setting range
(min. value | unit | max. value)
0
Read access
C00953
Parameter | Name:
C00953 | L_Interpolator_1: Speed-up
From version 04.00.00
FB L_Interpolator_1: Filter
Setting range
(min. value | unit | max. value)
0
Read access
C00959
Parameter | Name:
C00959 | L_Curve: Current output value
From version 11.00.00
FB L_Curve_1: Display of the current output value nOut_a
Display range
(min. value | unit | max. value)
-199.99
Subcodes
C00959/1
C00959/2
C00959/3
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
FB: Activation of signal interpolation and signal monitoring
0 Off
1 On
Lenze setting
0: Off
0: Off
0: Off
Write access
CINH
PLC STOP
FB: No. of interpolation steps
Write access
CINH
PLC STOP
FB: Limit value for missing data telegrams
Write access
CINH
PLC STOP
Write access
CINH
PLC STOP
%
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Info
L_Interpolator_1: Signal interpolation
L_Interpolator_1: Signal monitoring
L_Interpolator_1: Master value monitoring
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
65535 1
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
65535 5
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
100 0
No transfer
COM
MOT
Scaling factor: 1
199.99
Info
L_Curve_1: Current output value
L_Curve_2: Current output value
L_Curve_3: Current output value
No transfer
COM
MOT
Scaling factor: 100
Parameter reference
Parameter list | C00950
Data type: UNSIGNED_8
Index: 23625
= 5C49
d
h
Data type: UNSIGNED_16
Index: 23624
= 5C48
d
h
Data type: UNSIGNED_16
Index: 23623
= 5C47
d
h
Data type: UNSIGNED_8
Index: 23622
= 5C46
d
h
Data type: INTEGER_16
Index: 23616
= 5C40
d
h