Internal interfaces to the application
Relevant inputs at the
Identifier
DIS code | data type
Counting input DI1
bCountIn1_ResetCompare
bCountIn1_LoadStartValue
Counting input DI6
bCountIn6_ResetCompare
bCountIn6_LoadStartValue
Relevant outputs at the
Identifier
DIS code | data type
Counting input DI1
bCountIn1_Compare
wCountIn1_HW
wCountIn1_LW
Counting input DI6
bCountIn6_Compare
wCountIn6_HW
wCountIn6_LW
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
LS_DigitalInput
Information/possible settings
Reset status signal "Comparison value reached"
BOOL
FALSE TRUE The output bCountIn1_Compare is reset to FALSE.
Load starting value into counter
BOOL
FALSE TRUE The starting value set in
Reset status signal "Comparison value reached"
BOOL
FALSE TRUE The output bCountIn6_Compare is reset to FALSE.
Load starting value into counter
BOOL
FALSE TRUE The starting value set in
LS_DigitalInput
Value/meaning
Status signal "Comparison value reached"
BOOL
FALSE Current count value < comparison value (C02840/2)
TRUE Current count value ≥ comparison value (C02840/2)
Current count value
• Output as High and Low word (without sign)
• Possible counting range: 0 ... 2
C02841/1
| WORD
Status signal "Comparison value reached"
BOOL
FALSE Current count value < comparison value (C02840/4)
TRUE Current count value ≥ comparison value (C02840/4)
Current count value
• Output as High and Low word (without sign)
• Possible counting range: 0 ... 2
C02841/2
| WORD
L
8400 HighLine C | Reference manual
system block:
C02840/1
value.
C02840/3
value.
system block:
31
- 1
31
- 1
I/O terminals
Digital input terminals
is accepted as the current count
is accepted as the current count
321