Lenze L-force HighLine C 8400 Series Reference Manual page 958

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Parameter reference
Parameter list | C01304
C01304
Parameter | Name:
C01304 | Profile data: Deceleration
Selection of the decelerations for profiles 1 ... 15
Setting range
(min. value | unit | max. value)
-214748.3647
Subcodes
C01304/1
C01304/...
C01304/15
Read access
C01305
Parameter | Name:
C01305 | Profile data: Final speed
Selection of the final speeds for profiles 1 ... 15
• For profile linkage with overchange.
Setting range
(min. value | unit | max. value)
-214748.3647
Subcodes
C01305/1
C01305/...
C01305/15
Read access
C01306
Parameter | Name:
C01306 | Profile data: S-ramp time
Selection of the S-ramp times for profiles 1 ... 15
• The maximum S-ramp time is the time in which the maximum acceleration or the maximum deceleration is
reached along a ramp (jerk limitation).
Setting range
(min. value | unit | max. value)
0.000
Subcodes
C01306/1
C01306/...
C01306/15
Read access
958
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
unit/s2
214748.3647
Lenze setting
720.0000 unit/s2
Write access
CINH
PLC STOP
unit/s
214748.3647
Lenze setting
0.0000 unit/s
Write access
CINH
PLC STOP
s
Lenze setting
0.000 s
Write access
CINH
PLC STOP
L
Info
Profiles 1 ... 15: Deceleration
No transfer
COM
MOT
Scaling factor: 10000
Info
Profiles 1 ... 15: Final speed
No transfer
COM
MOT
Scaling factor: 10000
10.000
Info
Profiles 1 ... 15: S-ramp time
No transfer
COM
MOT
Scaling factor: 1000
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: INTEGER_32
Index: 23271
= 5AE7
d
h
Profile entry
Data type: INTEGER_32
Index: 23270
= 5AE6
d
h
Profile entry
Data type: UNSIGNED_16
Index: 23269
= 5AE5
d
h
Profile entry

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents