Lenze L-force HighLine C 8400 Series Reference Manual page 793

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

C00463
Parameter | Name:
C00463 | Remote: MCK control
From version 06.00.00
This parameter serves to control the functions of the Motion Control Kernel for
Setting range
(min. hex value | max. hex value)
0x00000000
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 16
Bit 17
Bit 18
Bit 19
Bit 20
Bit 21
Bit 22
Bit 23
Bit 24
Bit 25
Bit 26
Bit 27
Bit 28
Bit 29
Bit 30
Bit 31
Subcodes
C00463/1
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
= bit set)
OpMode_Bit0
OpMode_Bit1
OpMode_Bit2
OpMode_Bit3
ManJogPos
ManJogNeg
ManExecute2ndSpeed
ReleaseLimitSwitch
HomStartStop
HomSetPos
HomResetPos
EnableSpeedOverride
EnableAccOverride
EnableSRampOverride
PosTeachSetPos
PosTeachActPos
PosExecute
PosFinishTarget
PosDisableFollowProfile
PosStop
PosModeBit0
PosModeBit1
PosModeBit2
PosModeBit3
ProfileNo_Bit0
ProfileNo_Bit1
ProfileNo_Bit2
ProfileNo_Bit3
ProfileNo_Bit4
ProfileNo_Bit5
ProfileNo_Bit6
ProfileNo_Bit7
Lenze setting
0
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
0xFFFFFFFF
Info
Remote: MCK control
No transfer
COM
MOT
Parameter reference
Parameter list | C00463
Data type: UNSIGNED_32
Index: 24112
= 5E30
d
PC manual
control.
h
793

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series