Tip!
The following guide value applies to a correctly set slip compensation:
• Deviation from the rated motor speed
of the rated motor speed and loads
• Greater deviations are possible in the field weakening range.
• If
• Negative slip
drive behaviour at heavy load impulses or applications requiring a significant
speed drop under load.
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
C00021
is set too high, the drive may get unstable.
(C00021
< 0) with V/f characteristic control results in "smoother"
L
8400 HighLine C | Reference manual
Motor control (MCTRL)
Parameterisable additional functions
1% for the speed range of 10 % ... 100 %
rated motor torque.