Lenze L-force HighLine C 8400 Series Reference Manual page 847

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

Parameter | Name:
C00760 | LA_SwitchPos: Analog connection list
C00760/15
C00760/16
C00760/17
C00760/18
C00760/19
C00760/20
C00760/21
C00760/22
C00760/23
C00760/24
C00760/25
Read access
C00761
Parameter | Name:
C00761 | LA_SwitchPos: Digital connection list
Connection parameters for "Switch-off positioning" application: Binary inputs
• Selection of the binary output signals to be connected to the binary input signals
• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the
subcodes.
Selection list
See
selection list - digital signals
Subcodes
C00761/1
C00761/2
C00761/3
C00761/4
C00761/5
C00761/6
C00761/7
C00761/8
C00761/9
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
Write access
CINH
PLC STOP
Lenze setting
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
0: Not connected
L
8400 HighLine C | Reference manual
LA_SwitchPos: nGPCompareIn1_a
(input for comparison operation analog signal 1)
LA_SwitchPos: nGPCompareIn2_a
(input for comparison operation analog signal 2)
LA_SwitchPos: wSMCtrl
(interface to optional safety system)
Reserved
Reserved
Reserved
Reserved
LA_SwitchPos: wFreeIn1
(input for user signal 1)
LA_SwitchPos: wFreeIn2
(input for user signal 2)
LA_SwitchPos: wFreeIn3
(input for user signal 3)
LA_SwitchPos: wFreeIn4
(input for user signal 4)
No transfer
COM
MOT
Scaling factor: 1
Info
LA_SwitchPos: bCInh
(control input for setting controller inhibit)
LA_SwitchPos: bFailReset
(control input for error acknowledgement)
LA_SwitchPos: bSetQuickstop
(control input for quick stop request)
LA_SwitchPos: bSetDCBrake
(control input for DC-injection braking request)
LA_SwitchPos: bRFG_Stop
(control input for stopping the speed ramp function
generator)
LA_SwitchPos: bSetSpeedCcw
(control input for change of direction of rotation)
LA_SwitchPos: bRLQCw
(control input for activation of CW rotation (fail-safe))
LA_SwitchPos: bRLQCcw
(control input for activation of CCW rotation (fail-safe))
LA_SwitchPos: bJogCtrlInputSel1
(selection input 1 for binary coded selection of the
switch-off position 1 ... 3)
Parameter reference
Parameter list | C00761
Data type: UNSIGNED_16
Index: 23815
= 5D07
d
h
Data type: UNSIGNED_16
Index: 23814
= 5D06
d
h
847