Lenze L-force HighLine C 8400 Series Reference Manual page 77

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

4. Recommendation: Set an offset in the
to prevent the machine from stopping at an activated limit switch.
– Background: The load machine can also leave the travel range limit switch. There
follows a return to the home position that was set with the positive edge of the
travel range limit switch.
5. Set suitable profile parameters for the homing:
Parameter
S-ramp time
(C01226/1)
Start speed
(C01224/1)
Start acceleration
(C01225/1)
6. After setting the parameters for the homing, click the Back button to change back to
the Overview  Signal flow dialog level.
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
8400 HighLine C | Reference manual
Commissioning of the "Table positioning" technology application
Homing home offset input field (C01227/1)
Lenze setting
Info
Value Unit
0.000 s
S-ramp time for reference search/homing.
• Setting "0 s" ≡ no rounding
720.0000 unit/s
Starting speed for approaching the pre-stop signals.
2
720.0000 unit/s
Starting acceleration for the starting speed ramps.
L
Commissioning
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents