Lenze L-force HighLine C 8400 Series Reference Manual page 735

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

C00115
Parameter | Name:
C00115 | DI 1/2 & 6/7: Fct.
Function assignment of the digital terminals DI1/2 and DI6/7
Selection list
Subcodes
C00115/1
C00115/2
Read access
C00117
Parameter | Name:
C00117 | Status of brake output BD
Status message of brake output
Selection list
(read only)
Read access
C00118
Parameter | Name:
C00118 | DigOutX: Inversion
The polarity of each digital output of the device can be inverted via this bit field.
Setting range
(min. hex value | max. hex value)
0x00
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 DI1(6)=In / DI2(7)=In
1 DI1(6)=FreqIn / DI2(7)=In
2 DI1(6)&DI2(7)=FreqIn (2-track)
3 DI1(6)=FreqIn / DI2(7)=direction
4 DI1(6)=CountIn / DI2(7)=In
Lenze setting
0: DI1(6)=In / DI2(7)=In
0: DI1(6)=In / DI2(7)=In
Write access
CINH
PLC STOP
0 Inactive
1 Active
Write access
CINH
PLC STOP
= bit set)
Relay inverted
DO1 inverted
DO2 inverted
DO3 inverted
High current inverted
Reserved
Reserved
Reserved
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Digital input
Info
DI1/6 = digital input
DI2/7 = digital input
DI1/6 = 1-track frequency input
DI2/7 = digital input
DI1/6 and DI2/7 = 2-track frequency input
DI1/6 = 1-track frequency input
DI2/7 = specification of direction
DI1/6 = counter input
DI2/7 = digital input
Info
Function assignment of DI1 and DI2
Function assignment of DI6 and DI7
No transfer
COM
MOT
Scaling factor: 1
Info
Brake output is inactive
Brake output is active
No transfer
COM
MOT
Scaling factor: 1
Lenze setting
0xFF 0x00 (decimal: 0)
Info
Relay inversion
Inversion of digital output 1
Inversion of digital output 2
Inversion of digital output 3
Inversion of high-current output
No transfer
COM
MOT
Parameter reference
Parameter list | C00115
Data type: UNSIGNED_8
Index: 24460
= 5F8C
d
terminals:
Function assignment
Data type: UNSIGNED_8
Index: 24458
= 5F8A
d
Data type: UNSIGNED_8
Index: 24457
= 5F89
d
Digital output terminals
735
h
h
h

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents