C00487
Parameter | Name:
C00487 - Application units
From version 06.00.00
SB LS_DisFree_a: Display of the input values in a configurable application unit
Display range
(min. value | unit | max. value)
-21474836.47
Subcodes
C00487/1
C00487/2
C00487/3
C00487/4
Read access
C00488
Parameter | Name:
C00488 | L_JogCtrlEdgeDetect
From version 02.00.00
The
L_JogCtrlExtension_1
• Selection whether the corresponding function is to be activated by edge or level.
Selection list
Subcodes
C00488/1
C00488/2
C00488/3
C00488/4
C00488/5
C00488/6
Read access
C00490
Parameter | Name:
C00490 | Position encoder selection
Selection of the feedback system for the generation of the actual position on the load
Selection list
(Lenze setting printed in bold)
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
units
21474836.47
Write access
CINH
PLC STOP
FB: Signal methodology
0 Level
1 Edge
Lenze setting
0: Level
0: Level
0: Level
0: Level
0: Level
0: Level
Write access
CINH
PLC STOP
0 No sensor
1 Sensor signal FreqIn12
2 Encoder signal FreqIn67
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Display of internal process factors in application units
Info
Application units 1
Application units 2
Application units 3
Application units 4
No transfer
COM
MOT
Scaling factor: 100
Info
InputSens.SlowDown1
• Selection of edge or level for starting slow-down
function 1
InputSens.Stop1
• Selection of edge or level for stop function 1
InputSens.SlowDown2
• Selection of edge or level for starting slow-down
function 2
InputSens.Stop2
• Selection of edge or level for stop function 2
InputSens.SlowDown3
• Selection of edge or level for starting slow-down
function 3
InputSens.Stop3
• Selection of edge or level for stop function 3
No transfer
COM
MOT
Scaling factor: 1
Info
No encoder available on the load
Position encoder signal is fed via digital inputs DI1 and
DI2
Position encoder signal is fed via digital inputs DI6 and
DI7
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00487
Data type: INTEGER_32
Index: 24088
= 5E18
d
h
Data type: UNSIGNED_8
Index: 24087
= 5E17
d
h
Data type: UNSIGNED_8
Index: 24085
= 5E15
d
h
Encoder/feedback system
801