Lenze L-force HighLine C 8400 Series Reference Manual page 602

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Diagnostics & error management
Error messages of the operating system
dF14: SW-HW invalid [xx.0145.00014]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Device error
dF18: BU RCOM error [xx.0145.00024]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Device error
dF25: CU RCOM error [xx.0145.00025]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Mains switching too frequent.
• Cyclic mains switching every 3 minutes is permissible.
dF26: Appl. watchdog [xx.0145.00026]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Time-out of the application. The required computing
time of the application exceeds the available computing
time.
dF21: BU watchdog [xx.0145.00033]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Device error
dF22: CU watchdog [xx.0145.00034]
Response (Lenze setting printed in bold)
0: No Reaction
Cause
Device error
602
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
1: Fault
2: Trouble
3: TroubleQuickStop
L
4: WarningLocked
5: Warning
6: Information
Remedy
Consultation with Lenze required.
4: WarningLocked
5: Warning
6: Information
Remedy
Consultation with Lenze required.
4: WarningLocked
5: Warning
6: Information
Remedy
• After switching the mains 3 times in one minute,
there must be a switching pause of 9 minutes.
• If the problem occurs again, you needs to consult
Lenze.
Setting:
C00580/1
(
Adjustable response)
4: WarningLocked
5: Warning
6: Information
Remedy
Reduction of the function block interconnection or the
complexity of the application.
4: WarningLocked
5: Warning
6: Information
Remedy
Consultation with Lenze required.
4: WarningLocked
5: Warning
6: Information
Remedy
Consultation with Lenze required.
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents