8400 HighLine C | Reference manual
Motor control (MCTRL)
V/f characteristic control - energy-saving (VFCplusEco)
5.5.2
Comparison of VFCplusEco - VFCplus
The following characteristics show the impact of the energy-saving V/f characteristic
control (VFCplusEco) compared to the standard V/f characteristic control (VFCplus).
The characteristics were recorded with a standard asynchronous motor 2.2 kW with
energy efficiency class IE1 at speed = 600 rpm.
scaled torque in [%]
efficiency in [%]
motor voltage in [V]
power factor
electrical power in [W]
[5-8]
Comparison of VFCplusEco - VFCplus
172