Internal Interfaces | "Ls_Touchprobe" System Block - Lenze L-force HighLine C 8400 Series Reference Manual

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
I/O terminals
Touch probe detection
6.4.2

Internal interfaces | "LS_TouchProbe" system block

The LS_TouchProbe system block provides the internal interfaces for touch probe detection
in the function block editor:
Inputs
Input
bDisableTPDigIn3...7
bDisableTPDigIn3...5Rising
bDisableTPDigIn3...5Falling
bEnableTPDigIn3...5Window
Outputs
Output
bTPDigIn3...7Received
dnTPDigIn3...7Position_p
348
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Information/possible settings
Data type
DI3 ... DI7: Dynamically deactivate TP function
BOOL
TRUE TP function is deactivated.
DI3 ... DI5: Dynamically deactivate detection of rising edges
BOOL
TRUE Detection of rising edges is deactivated.
DI3 ... DI5: Dynamically deactivate detection of falling edges
BOOL
TRUE Detection of falling edges is deactivated.
DI3 ... DI5: Activate acceptance window
BOOL
TRUE Acceptance window function is active:
• If the actual position is outside the acceptance window, whose
starting position is set in
in C02814/x, touch probe is automatically deactivated.
Value/meaning
Data type
TRUE DI3 ... DI7: Touch probe received.
• The signal is only pending for one task cycle (1 ms).
BOOL
DI3 ... DI7: Position measured by touch probe in [units]
DINT
L
C02813/x
and whose end position is set
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011