Lenze L-force HighLine C 8400 Series Reference Manual page 798

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Parameter reference
Parameter list | C00477
C00477
Parameter | Name:
C00477 | LS_ParFree_2
From version 11.00.00
SB LS_ParFree_2: Setting of the words to be output
Setting range
(min. hex value | max. hex value)
0x0000
Value is bit-coded:
Bit 0 Bit0
Bit 15 Bit15
Subcodes
C00477/1
C00477/...
C00477/32
Read access
C00478
Parameter | Name:
C00478 | LS_ParFree_v_2
From version 11.00.00
SB LS_ParFree_v_2: Setting of the speed signals to be output
Setting range
(min. value | unit | max. value)
-32767
Subcodes
C00478/1
C00478/...
C00478/8
Read access
C00479
Parameter | Name:
C00479 | LS_ParFree32
From version 11.00.00
SB LS_ParFree32: Setting of the 32-bit values to be output
Setting range
(min. value | unit | max. value)
-2147483647
Subcodes
C00479/1
C00479/...
C00479/8
Read access
798
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
... ...
Lenze setting
0
Write access
CINH
PLC STOP
Incr./ms
Lenze setting
0 incr./ms
Write access
CINH
PLC STOP
2147483647
Lenze setting
0
Write access
CINH
PLC STOP
L
0xFFFF
Info
Value for output wC477_1 ... wC477_32
No transfer
COM
MOT
32767
Info
Values for output nC478_1_v ... nC478_8_v
No transfer
COM
MOT
Scaling factor: 1
Info
Values for output dnC479_1 ... dnC479_8
No transfer
COM
MOT
Scaling factor: 1
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_16
Index: 24098
= 5E22
d
h
Data type: INTEGER_16
Index: 24097
= 5E21
d
h
Data type: INTEGER_32
Index: 24096
= 5E20
d
h