7.5.6

Analog comparison

This function compares two analog signals and can be used e.g. to realise a trigger. The
comparison operation, hysteresis and window size can be parameterised.
[7-10] GeneralPurpose function "Analog comparison"
Parameter
C00680
C00681
C00682
 For a detailed functional description see FB L_Compare.
7.5.7

Binary signal monitor

This function serves to output four binary signals selected from a list of all binary output
signals available in the drive controller. You can set an inversion of the output signals.
[7-11] GeneralPurpose function "Binary signal monitor"
Parameter
C00411/1...4
C00412
 For a detailed functional description see FB L_SignalMonitor_b.
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
C00681
C00830/16
nGPCompareIn1_a
C00830/17
nGPCompareIn2_a
Info
L_Compare_1: Fct.
L_Compare_1: Hysteresis
L_Compare_1: Window
C00411/1
C00411/2
C00411/3
C00411/4
Info
L_SignalMonitor_b: Signal 1 ... 4
L_SignalMonitor_b: Inversion
L
8400 HighLine C | Reference manual
"GeneralPurpose" functions
C00682
bGPCompareOut
f =
C00680
C00412 - Bit 0
0
bGPSignalOut1
1
C00412 - Bit 1
0
bGPSignalOut2
1
C00412 - Bit 2
0
bGPSignalOut3
1
C00412 - Bit 3
0
bGPSignalOut4
1
Technology applications
Lenze setting
Value Unit
6: |In1| < |In2|
0.50 %
2.00 %
Lenze setting
Value Unit
0: Not connected
Bit coded