Lenze L-force HighLine C 8400 Series Reference Manual page 503

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

Mode 12: >_Lp
 Positive travel range limit switch
Mode 12
Lp
Ln
Functional sequence:
1. Movement in positive direction with start profile data set.
2. Positive edge of the travel range limit switch sets reference.
Note!
The load machine can also leave the travel range limit switch. There follows a
return to the home position that was set with the positive edge of the travel
range limit switch.
• It is possible that, as a result, the machine will remain on an operated limit
switch.
• It is therefore recommended that a home value offset be set in
order to release the operated limit switch.
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0
>
Start speed
Inactive
Inactive
L
8400 HighLine C | Reference manual
Basic drive functions (MCK)
Lp
Offset path
Inactive
Inactive
Inactive
Active
Homing
1
Sequence profile (optional)
Profile speed
Active
Active
C01227/1
in
503