Lenze L-force HighLine C 8400 Series Reference Manual page 171

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

Parameter
Info
1
C00056/2
Actual torque value
2
C00830/4
Limitation of torque in motor mode
3
C00830/5
Limitation of torque in generator mode
4
C00054
Motor current
5
C00022
Imax in motor mode
6
C00023
Imax in generator mode
7
C00074
Ti Imax controller
8
C00073
Vp Imax controller
9
C00830/3
Speed setpoint
10
C00909/1
Max. pos. speed
11
C00909/2
Max. neg. speed
12
C00105
Decel. time - quick stop
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Parameter
Info
13
C00910/1
Max. pos. output frequency
14
C00910/2
Max. neg. output frequency
15
C00021
Slip compensation
16
C00051
Actual speed value
17
C00050
Speed setpoint
18
C00056/2
Actual torque value
19
C00058
Output frequency
20
C00830/26
MCTRL: nBoost_a
21
C00015
V/f base frequency
22
C00016
Vmin boost
23
C00979/2
Cosine phi set
24
C00979/1
Cosine phi act
25
C00083
Motor rotor time constant
Parameter
Info
26
C00975
VFC-ECO: Vp
27
C00976
VFC-ECO: Ti
28
C00977
VFC-ECO: Minimum voltage V/f
29
C00982
VFC-ECO: Voltage reduction ramp
30
C00978
VFC-ECO: Voltage reduction
31
C00018
Switching frequency
32
C00830/32
MCTRL: nPWMAngleOffset_a
33
C00830/31
MCTRL: nVoltageAdd_a
34
C00052
Motor voltage
35
C00980/1
Active output power
36
C00980/2
Apparent output power
37
C00981/1
Output energy in motor mode
38
C00981/2
Output energy in generator mode

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series