8400 HighLine C | Reference manual
I/O terminals
User-defined terminal assignment
Configuration parameters for the inputs of the technology application
The following parameters can be used to change the preconfigured assignment of the
application inputs:
Parameter
TA "Actuating drive speed":
C00700/x
C00701/x
TA "Table positioning":
C00710/x
C00711/x
TA "Switch-off positioning":
C00760/x
C00761/x
Example
Task: Starting from the preset technology application "Actuating drive speed" and the
"Terminals 0" control mode, the DI2 digital input is to be used for choosing an alternative
acceleration/deceleration time for the main setpoint instead of for choosing the fixed
setpoint 2/3. To do this, the DI2 digital input is not to be linked to the bJogSpeed2 input but
to the bJogRamp1 input of the application module.
Procedure:
1. Use the keypad to go to the menu level Applications  Actuating drive speed (conf.).
This menu level contains all the configuration parameters of the "Actuating drive
speed" technology application".
2. Navigate to the configuration parameter LA_NCtrl: bJogSpeed2 (C00701/10) which
represents the logical signal link of the application input bJogSpeed2.
3. Change the setting of C00701/10:
Change selection "16001: DigIn_bIn2" in selection "0: Not interconnected".
4. Navigate to the configuration parameter LA_NCtrl: bJogRamp1 (C00701/13) which
represents the logical signal link of the application input bJogRamp1.
5. Change the setting of C00701/13:
Change selection "0: Not interconnected" in selection "16001: DigIn_bIn2".
Tip!
The example shows that, for each input of the application block, the associated
configuration parameter
source that you enter.
354
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Info
Configuration parameters ( 384)
Analog connection list
Digital connection list
Configuration parameters ( 413)
Analog connection list
Digital connection list
Configuration parameters ( 441)
Analog connection list
Digital connection list
Configuration parameters
(C00700/x
L
( 384)
or C00701/x) is only allowed to contain one
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011