C00995
Parameter | Name:
C00995 | SLPSM: Controlled current setpoint
From version 10.00.00
Setting range
(min. value | unit | max. value)
5.00
Subcodes
C00995/1
C00995/2
Read access
C00996
Parameter | Name:
C00996 | SLPSM: Switching speed
From version 10.00.00
Setting range
(min. value | unit | max. value)
0.00
Subcodes
C00996/1
C00996/2
Read access
C00997
Parameter | Name:
C00997 | SLPSM: Filter cutoff frequency
From version 10.00.00
Setting range
(min. value | unit | max. value)
0.00
Read access
C00998
Parameter | Name:
C00998 | SLPSM: Filter time rotor position
From version 10.00.00
Setting range
(min. value | unit | max. value)
0.5
Subcodes
C00998/1
C00998/2
Read access
C00999
Parameter | Name:
C00999 | SLPSM: PLL gain
From version 10.00.00
Setting range
(min. value | unit | max. value)
0
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
%
Lenze setting
100.00 %
20.00 %
Write access
CINH
PLC STOP
%
Lenze setting
13.00 %
8.00 %
Write access
CINH
PLC STOP
%
Write access
CINH
PLC STOP
ms
Lenze setting
3.0 ms
5.0 ms
Write access
CINH
PLC STOP
%
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Sensorless control for synchronous motor
400.00
Info
SLPSM: Controlled accelerating current
SLPSM: Controlled standstill current
No transfer
COM
MOT
Scaling factor: 100
Sensorless control for synchronous motor
100.00
Info
SLPSM: Switching speed, closed-loop control
SLPSM: Switching speed, open-loop control
No transfer
COM
MOT
Scaling factor: 100
Sensorless control for synchronous motor
Lenze setting
100.00 5.00 %
No transfer
COM
MOT
Scaling factor: 100
Sensorless control for synchronous motor
20.0
Info
SLPSM: Filter time rotor position
SLPSM: Filter time actual speed value
No transfer
COM
MOT
Scaling factor: 10
Sensorless control for synchronous motor
Lenze setting
1000 400 %
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00995
Data type: UNSIGNED_16
Index: 23580
= 5C1C
d
h
Data type: INTEGER_16
Index: 23579
= 5C1B
d
h
Data type: INTEGER_16
Index: 23578
= 5C1A
d
h
Data type: INTEGER_16
Index: 23577
= 5C19
d
h
Data type: INTEGER_16
Index: 23576
= 5C18
d
h
911