8400 HighLine C | Reference manual
Parameter reference
Parameter list | C01233
C01233
Parameter | Name:
C01233 | MCK: Manual jog S-ramp time
S-ramp time for manual jog
• Setting "0 s" ≡ no rounding
Setting range
(min. value | unit | max. value)
0.000
Subcodes
C01233/1
Read access
C01234
Parameter | Name:
C01234 | MCK: Manual jog breakpoints
Breakpoint positions for manual jog
• The drive stops at the parameterised positions if these are located in the manual jog direction and the
approaching of the breakpoints is switched on in
Setting range
(min. value | unit | max. value)
-214748.3647
Subcodes
C01234/1
C01234/2
C01234/3
C01234/4
Read access
C01235
Parameter | Name:
C01235 | MCK: Manual jog waiting times
Waiting times for manual jog
Setting range
(min. value | unit | max. value)
0.000
Subcodes
C01235/1
Read access
C01236
Parameter | Name:
C01236 | MCK: Speed follower
Speeds for position follower
Setting range
(min. value | unit | max. value)
-214748.3647
Subcodes
C01236/1
Read access
946
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
s
Lenze setting
0.000 s
Write access
CINH
PLC STOP
unit
214748.3647
Lenze setting
0.0000 unit
0.0000 unit
0.0000 unit
0.0000 unit
Write access
CINH
PLC STOP
s
Lenze setting
5.000 s
Write access
CINH
PLC STOP
units/s
214748.3647
Lenze setting
360.0000 units/s
Write access
CINH
PLC STOP
L
10.000
Info
Manual jog: S-ramp time
• S-ramp time for the manual speed ramps.
No transfer
COM
MOT
Scaling factor: 1000
C01230
via bit 0.
Info
Manual jog: Breakpoint 1
Manual jog: Breakpoint 2
Manual jog: Breakpoint 3
Manual jog: Breakpoint 4
No transfer
COM
MOT
Scaling factor: 10000
65.000
Info
Manual jog: Waiting time 2nd speed
• Time after which the first manual speed (C01231/1) is
accelerated to the second manual speed (C01231/2).
No transfer
COM
MOT
Scaling factor: 1000
Info
PosFollower: Sync. speed
• Synchronisation speed for approaching the setpoint
position of the master.
No transfer
COM
MOT
Scaling factor: 10000
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_16
Index: 23342
= 5B2E
d
h
Manual jog
Data type: INTEGER_32
Index: 23341
= 5B2D
d
h
Manual jog
Data type: UNSIGNED_16
Index: 23340
= 5B2C
d
h
Manual jog
Data type: INTEGER_32
Index: 23339
= 5B2B
d
h
Position follower