Lenze L-force HighLine C 8400 Series Reference Manual page 967

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

C02611
Parameter | Name:
C02611 | MCK: Limitations
Speed setpoint limits for the determination of limited validity ranges
Note:
Traversing with setpoints through resulting blocking zones is executed with the ramp set in C02610/2.
Speed Min/Max
Setting range
(min. value | unit | max. value)
0.00
Subcodes
C02611/1
C02611/2
C02611/3
C02611/4
Read access
C02652
Parameter | Name:
C02652 | Memorise positions at power-off
From version 11.00.00
Setting range
(min. hex value | max. hex value)
0x0000
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
%
Lenze setting
199.99 %
0.00 %
0.00 %
199.99 %
Write access
CINH
PLC STOP
= bit set)
Actual MCTRL position
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
199.99
Info
MCK: Pos. max. speed
• Upper limit of the speed setpoint limitation in
positive direction of rotation.
MCK: Pos. min. speed
• Lower limit of the speed setpoint limitation in
positive direction of rotation.
MCK: Neg. min. speed
• Lower limit of the speed setpoint limitation in
negative direction of rotation.
MCK: Neg. max. speed
• Upper limit of the speed setpoint limitation in
negative direction of rotation.
No transfer
COM
MOT
Scaling factor: 100
Lenze setting
0xFFFF 0x0000 (decimal: 0)
No transfer
COM
MOT
Parameter reference
Parameter list | C02611
Data type: INTEGER_16
Index: 21964
= 55CC
d
h
Data type: UNSIGNED_16
Index: 21923
= 55A3
d
h
967

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents