8400 HighLine C | Reference manual
Motor control (MCTRL)
V/f characteristic control (VFCplus)
Tip!
Cases of application for this function:
• Operation of reluctance motors or synchronous motors during controlled
acceleration (reduction of natural frequencies caused by wrong excitation).
• Adaptation of the voltage requirement for the motor, depending on specific
load conditions.
Proceed as follows to open the dialog for parameterising the motor control:
1. »Engineer« Go to the Project view and select the 8400 HighLine controller.
2. Go to Workspace and change to the Application parameters tab.
3. Select the motor control "10: VFCplus: V/f definable" from the Overview dialog box
in the Motor control list field:
4. Click the Motor control V/f definable button to change to the Overview  Motor
control V/f dialog box.
• This dialog level only shows a simplified signal flow with the most important
parameters.
• When you click the >>More details button in the left-most position, a signal
flow with more details/parameters is displayed.