8400 HighLine C | Reference manual
Parameter reference
Parameter list | C00005
C00005
Parameter | Name:
C00005 | Application
Selection of the technology application
Selection list
(Lenze setting printed in bold)
1000 Actuating drive speed
2000 Table positioning
3000 Switch-off positioning
Read access
C00006
Parameter | Name:
C00006 | Motor control
Selection of the motor control mode
Selection list
(Lenze setting printed in bold)
712
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 Wiring has changed
Write access
CINH
PLC STOP
2 SC: Servo control ASM
3 SLPSM: Sensorless PSM
4 SLVC: Vector control
6 VFCplus: V/f linear
7 VFCplus: V/f linear + encoder
L
Info
This display appears if the FB interconnection has been
changed in the application level using the FB Editor.
This technology application is used to solve speed-
controlled drive tasks, e.g. conveying belts.
This technology application is used to solve position-
controlled drive tasks which are usually controlled by a
higher-level control system using a fieldbus.
From version 04.00.00
This technology application is used to solve speed-
controlled drive tasks which require a pre-switch off or
stopping at certain positions, e.g. roller conveyors and
conveying belts. This is implemented by connecting
switch-off sensors.
No transfer
COM
MOT
Scaling factor: 1
Motor control
Info
This control type is used for the servo control of an
asynchronous motor.
• The control type requires a speed feedback via an
encoder mounted to the motor!
Servo control
From version 10.00.00
This control type is used for the sensorless control of a
synchronous motor.
Sensorless control for synchronous motors
This control type is used for sensorless vector control of
an asynchronous motor.
• The control type requires motor parameters to be set
as exactly as possible!
Sensorless vector control
This control type is used for the speed control of an
asynchronous motor via a linear V/f characteristic and is
the simplest control type.
• For setting the V/f characteristic, only the rated
frequency (C00089) and the rated voltage (C00090) of
the motor have to be entered.
V/f characteristic control
This control type is used for speed control of an
asynchronous motor via a linear V/f characteristic.
• The control type requires a speed feedback via an
encoder mounted to the motor!
• For setting the V/f characteristic, only the rated
frequency (C00089) and the rated voltage (C00090) of
the motor have to be entered.
V/f control
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_16
Index: 24570
= 5FFA
d
h
Data type: UNSIGNED_8
Index: 24569
= 5FF9
d
h
(MCTRL):