Sync phase position
The phase position determines the zero-time of the internal system cycle with regard to
the synchronisation signal (bus cycle). Since PDO processing is an inherent part of the
system part of the application, the instant of acceptance of the PDOs is postponed as well
by a changed phase position.
 If "0" is set, the internal system cycle starts at the same time as the synchronisation
signal.
 If a value > 0 is set, the internal system cycle starts by the set time earlier (the phase
position has a negative effect) than the synchronisation signal.
 Intelligent communication modules define the optimal time with activated
synchronisation by themselves. In this case, a manual change is not possible.
 For determining C01122, the point in time where all bus nodes have valid PDOs is
decisive.
Example: If the phase position is set to 550 μs, the system part of the application starts
550 μs before the arrival of the synchronisation signal.
Sync correction width
If the cycle times of the synchronisation signal and the phase-locking loop (PLL) are
different, the setting in
loop.
 The recommended reset time for the CAN bus as synchronisation source in case of
occurring deviations is 300 ns (Lenze setting).
 If synchronisation is not reached, select a higher correction width.
 The optimum setting depends on quartz precision and must be determined empirically
if required.
12.1

Internal interfaces | System block "LS_SyncManagement"

The SB LS_SyncManagement provides status information for synchronising the internal
time base:
Outputs
Identifier
bSyncSignalOK
bSyncPhaseOK
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Internal interfaces | System block "LS_SyncManagement"
C01124
defines the correction increments for the phase-locking
Value/meaning
Data type
TRUE Sync signal OK
BOOL
TRUE Sync phase position OK
BOOL