Touch Probe Positioning - Lenze L-force HighLine C 8400 Series Reference Manual

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8.8.2.4

Touch probe positioning

This function extension is available from version 06.00.00!
In case of a touch probe positioning, first the profile is executed according to the set profile
parameters. If a touch probe is detected during the process, it is automatically changed to
the profile defined in the "TP profile" profile parameter. This profile mode is also defined
via the mode selection like in the following profile start processes.
If no valid TP profile is set, the travel request is aborted ("PosStop").
Preconditions for touch probe positioning
 The mode of the current profile data set contains the setting "to TP".
 For absolute positioning, the home (reference) position must be known.
 In the corresponding profile data set, the following profile parameters must be set in
addition:
– TP profile (C1308/x)
– TP source (C1309/x)
 The touch probe interface is configured such that the selected TP source is enabled.
– See chapter entitled
Note!
Go to
the touch-probe sensor is to respond. In the Lenze setting of C02810/x, no touch
probe is detected!
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
"Touch probe
C02810/x
and select the edge, the digital input used for the connection of
L
8400 HighLine C | Reference manual
Basic drive functions (MCK)
detection".
( 343)
Positioning
527