Lenze L-force HighLine C 8400 Series Reference Manual page 927

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

C01085
Parameter | Name:
C01085 | LS_WriteParamList: Index
From version 04.00.00
Parameter
change-over: Parameter for entry 1 ... 32
Setting range
(min. value | unit | max. value)
0.000
Subcodes
C01085/1
C01085/...
C01085/32
Read access
C01086
Parameter | Name:
C01086 | LS_WriteParamList: WriteValue_1
From version 04.00.00
Parameter
change-over: Parameter values - value set 1
Setting range
(min. value | unit | max. value)
-2147483647
Subcodes
C01086/1
C01086/...
C01086/32
Read access
C01087
Parameter | Name:
C01087 | LS_WriteParamList: WriteValue_2
From version 04.00.00
Parameter
change-over: Parameter values - value set 2
Setting range
(min. value | unit | max. value)
-2147483647
Subcodes
C01087/1
C01087/...
C01087/32
Read access
C01088
Parameter | Name:
C01088 | LS_WriteParamList: WriteValue_3
From version 04.00.00
Parameter
change-over: Parameter values - value set 3
Setting range
(min. value | unit | max. value)
-2147483647
Subcodes
C01088/1
C01088/...
C01088/32
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Lenze setting
0.000
Write access
CINH
PLC STOP
2147483647
Lenze setting
0
Write access
CINH
PLC STOP
2147483647
Lenze setting
0
Write access
CINH
PLC STOP
2147483647
Lenze setting
0
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
16000.000
Info
Parameter for entries 1 ... 32
• Format: <code number>.<subcode number>
• Examples: "12.000" = C00012; "26.001" = C00026/1
No transfer
COM
MOT
Scaling factor: 1000
Info
Parameter values - value set 1
• Parameter values for the parameters defined in
C01085/1 ... 32.
No transfer
COM
MOT
Scaling factor: 1
Info
Parameter values - value set 2
• Parameter values for the parameters defined in
C01085/1 ... 32.
No transfer
COM
MOT
Scaling factor: 1
Info
Parameter values - value set 3
• Parameter values for the parameters defined in
C01085/1 ... 32.
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C01085
Data type: INTEGER_32
Index: 23490
= 5BC2
d
h
Data type: INTEGER_32
Index: 23489
= 5BC1
d
h
Data type: INTEGER_32
Index: 23488
= 5BC0
d
h
Data type: INTEGER_32
Index: 23487
= 5BBF
d
h
927