C01230
Parameter | Name:
C01230 | Manual jog: Setting
Settings for "Manual jog" mode
Setting range
(min. hex value | max. hex value)
0x00
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Read access
C01231
Parameter | Name:
C01231 | MCK: Manual jog speeds
Manual jog speeds
Setting range
(min. value | unit | max. value)
-214748.3647
Subcodes
C01231/1
C01231/2
Read access
C01232
Parameter | Name:
C01232 | MCK: Manual jog accelerations
Acceleration/deceleration for manual jog
Setting range
(min. value | unit | max. value)
-214748.3647
Subcodes
C01232/1
C01232/2
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
= bit set)
Breakpoints 1..4 on
Time-based start of 2nd speed
HW limit switch on
SW limit switch on
Reserved
Reserved
Reserved
Position controller off
Write access
CINH
PLC STOP
units/s
214748.3647
Lenze setting
360.0000 units/s
720.0000 units/s
Write access
CINH
PLC STOP
units/s2
214748.3647
Lenze setting
720.0000 units/s2
720.0000 units/s2
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
Lenze setting
0xFF 0x00 (decimal: 0)
Info
"1" ≡ approach of the parameterised breakpoint in
manual jog direction
"1" ≡ Automatic change-over to second manual speed
after the wating time set in C01235/1.
"1" ≡ Travel range monitoring via hardware limit switch
is active. The error response can be parameterised in
C00595/1
and C00595/2.
"1" ≡ Travel range monitoring via parameterised
software limit positions is active. The error response can
be parameterised in
"1" ≡ Position controller is deactivated. Thus, the
compensation of the following error is switched off.
No transfer
COM
MOT
Info
Manual jog: speed 1
• Regular manual speed
Manual jog: Speed 2
• Second manual speed (can be activated via MCK
control word)
No transfer
COM
MOT
Scaling factor: 10000
Info
Manual jog: Acceleration
• Acceleration for ramp-up to manual speed.
Manual jog: Deceleration
• Deceleration for manual speed ramp-down to
standstill.
No transfer
COM
MOT
Scaling factor: 10000
Parameter reference
Parameter list | C01230
Data type: UNSIGNED_8
Index: 23345
= 5B31
d
Manual jog
C00595/3
and C00595/4.
Data type: INTEGER_32
Index: 23344
= 5B30
d
Manual jog
Data type: INTEGER_32
Index: 23343
= 5B2F
d
Manual jog