8400 HighLine C | Reference manual
Motor control (MCTRL)
V/f characteristic control (VFCplus)
V/f characteristic control (VFC)
The accuracy of the torque limitation is limited because the actual torque (C00056/2) is
only calculated from the slip speed measured indirectly via the motor current.
V/f control (VFC + encoder)
The slip speed of the motor is available at the slip controller output. This leads to a high
accuracy for the actual torque (C00056/2) and the torque limitation.
[5-6]
Extract from the signal flow of the V/f control (VFC + encoder)
Parameter
1
C00056/2
2
C00830/29
3
C00830/28
4
C00054
5
C00022
6
C00023
7
C00074
8
C00073
164
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Info
Actual torque value
Limitation of torque in motor mode
Limitation of torque in generator mode
Motor current
Imax in motor mode
Imax in generator mode
Ti Imax controller
Vp Imax controller
L
Parameter
Info
9
C00830/22
MCTRL: nSpeedSetValue_a
10
C00909/1
Max. pos. speed
11
C00909/2
Max. neg. speed
12
C00105
Decel. time - quick stop
13
C00050
Speed setpoint
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011