8400 HighLine C | Reference manual
Parameter reference
Parameter list | C00727
C00727
Parameter | Name:
C00727 | LS_Keypad digital values
Execution of control commands for keypad operation
Setting range
(min. value | unit | max. value)
0
Subcodes
C00727/1
C00727/2
C00727/3
C00727/4
C00727/5
C00727/6
C00727/7
C00727/8
Read access
C00728
Parameter | Name:
C00728 | Keypad analog values
Selection of different setpoints when operating via keypad
Setting range
(min. value | unit | max. value)
-199.99
Subcodes
C00728/1
C00728/2
C00728/3
Read access
C00729
Parameter | Name:
C00729 | Remote: Setpoint selection
Setting range
(min. value | unit | max. value)
-199.99
Subcodes
C00729/1
C00729/2
Read access
C00730
Parameter | Name:
C00730 | Oscilloscope scanning interval
This code is for device-internal use only and must not be written to by the user!
C00731
Parameter | Name:
C00731 | Oscilloscope recording length
This code is for device-internal use only and must not be written to by the user!
C00732
Parameter | Name:
C00732 | Oscilloscope command
This code is for device-internal use only and must not be written to by the user!
844
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Lenze setting
0
0
0
0
0
0
0
0
Write access
CINH
PLC STOP
%
Lenze setting
100.00 %
100.00 %
0.00 %
Write access
CINH
PLC STOP
Lenze setting
0.00
0.00
Write access
CINH
PLC STOP
L
1
Info
"1" ≡ request quick stop
"1" ≡ request DC-injection braking
"1" ≡ request change of direction of rotation
"1" ≡ request fixed speed setpoint 1
"1" ≡ request fixed speed setpoint 2
"1" ≡ motor potentiometer: request activation
"1" ≡ motor potentiometer: request pos. acceleration
"1" ≡ motor potentiometer: request neg. acceleration
No transfer
COM
MOT
Scaling factor: 1
199.99
Info
Torque limit in motor mode
Torque limit in generator mode
Setpoint speed
No transfer
COM
MOT
Scaling factor: 100
199.99
Info
Remote: Setpoint keypad
Remote: Setpoint PC
No transfer
COM
MOT
Scaling factor: 100
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_8
Index: 23848
= 5D28
d
h
Data type: INTEGER_16
Index: 23847
= 5D27
d
h
Data type: INTEGER_16
Index: 23846
= 5D26
d
h
Data type: UNSIGNED_32
Index: 23845
= 5D25
d
h
Data type: UNSIGNED_32
Index: 23844
= 5D24
d
h
Data type: UNSIGNED_8
Index: 23843
= 5D23
d
h