8400 HighLine C | Reference manual
I/O terminals
Digital input terminals
Inputs
Identifier
DIS code | data type
Counting input DI1
bCountIn1_ResetCompare
bCountIn1_LoadStartValue
Frequency input DI1/DI2
bPosIn12_Load
(from version 06.00.00)
dnPosIn12_Set_p
(from version 06.00.00)
Counting input DI6
bCountIn6_ResetCompare
bCountIn6_LoadStartValue
Outputs
Identifier
DIS code | data type
bCInh
Digital inputs DI1 ... DI7
bIn1 ... bIn7
Counting input DI1
bCountIn1_Compare
wCountIn1_HW
wCountIn1_LW
Frequency input DI1/DI2
nFreqIn12_a
nFreqIn12_v
dnPosIn12_p
(from version 06.00.00)
bPosIn12_State
(from version 06.00.00)
324
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Information/possible settings
Using DI1(6) as counting input
Reset status signal "Comparison value reached"
BOOL
FALSE TRUE The output bCountIn1_Compare is reset to FALSE.
Load starting value into counter
BOOL
FALSE TRUE The starting value set in
Output of the encoder position of the DI1/DI2 frequency input
Load angle integrator with starting value and reset status signal
BOOL
TRUE Angle integrator is loaded with the value at dnPosIn12_Set_p and
Starting value for angle integrator
DINT
Using DI1(6) as counting input
Reset status signal "Comparison value reached"
BOOL
FALSE TRUE The output bCountIn6_Compare is reset to FALSE.
Load starting value into counter
BOOL
FALSE TRUE The starting value set in
Value/meaning
RFR digital input (controller enable)
C00443/2
| BOOL
Using DI1(6) and DI2(7) as digital inputs
Digital input DI1 ... DI7
C00443/2
| BOOL
Using DI1(6) as counting input
Status signal "Comparison value reached"
BOOL
FALSE Current count value < comparison value (C02840/2)
TRUE Current count value ≥ comparison value (C02840/2)
Current count value
• Output as High and Low word (without sign)
• Possible counting range: 0 ... 2
C02841/1
| WORD
Using DI1(6) and DI2(7) as frequency inputs
Output frequency as scaled analog signal in [%]
C00446/1
| INT
Output frequency as speed signal in [inc/ms]
C00445/1
| INT
Angle output signal
• 65536 [incr.] ≡ 1 encoder revolution
DINT
• Overflow is possible (display via bPosIn12_State)
Status signal "Overflow occurred/distance processed"
BOOL
• Status signal can be reset via bPosIn12_Load.
TRUE Overflow has occurred or distance is processed.
L
C02840/1
value.
bPosIn12_State is reset to FALSE.
C02840/3
value.
31
- 1
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
is accepted as the current count
is accepted as the current count