Lenze L-force HighLine C 8400 Series Reference Manual page 710

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Parameter reference
Parameter list
Parameter | Name:
C00002 | Device command
C00002/14
C00002/15
C00002/16
C00002/17
C00002/18
C00002/19
C00002/20
C00002/21
C00002/22
C00002/23
C00002/24
C00002/25
C00002/26
C00002/27
C00002/28
C00002/29
C00002/30
710
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0: Off / ready
0: Off / ready
1: On / start
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
0: Off / ready
L
Reserved
Reserved
Enable controller
"1" ≡ Enable controller
"0" ≡ Inhibit controller
Activate quick stop
"1" ≡ Activate quick stop
"0" ≡ Deactivate quick stop
Reserved
Reset error
• After the reset (acknowledgement) of the current
error, further errors may be pending which must also
be reset.
• The status determining error is displayed in C00168.
• The current error is displayed in C00170.
Reserved
Delete logbook
• All entries in the logbook of the controller are deleted.
• In the logbook, information on the error history is
saved.
Reserved
Motor parameter identification
• This device command serves to carry out automatic
motor parameter identification.
• The device command is only executed when the drive
controller is in the "SwitchedOn" status.
• In order to identify the motor parameters, the
controller must be enabled after this device
command.
From version
10.00.00, the identification method can
be selected in C02867.
Automatic motor parameter identification
Reserved
Reserved
CAN reset node
• Reinitialise "CAN on board" interface.
• Required when changing the baud rate, node address,
or identifiers.
System bus "CAN on board"
Device search function
From version 06.00.00
• This device command serves to optically locate a
controller connected online (e.g. for maintenance
work).
Device search function
Check MasterPin
From version 06.00.00
Unlocking the controller with a MasterPin
Set binding ID
From version 06.00.00
Device personalisation
Delete binding ID
From version 06.00.00
Device personalisation
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_8
Index: 24573
= 5FFD
d
h

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents