Lenze L-force HighLine C 8400 Series Reference Manual page 79

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

3. Set the profile parameters:
Parameter
Profile x: Mode
(C01300/x)
Profile x: Position
(C01301/x)
Profile x: Speed
(C01302/x)
Profile x: Acceleration
(C01303/x)
Profile x: Deceleration
(C01304/x)
Profile x: S-ramp time
(C01306/x)
Profile x: Final speed
(C01305/x)
Profile x: Sequence profile
(C01307/x)
Profile x: TP profile
(C01308/x)
Profile x: TP source
(C01308/x)
4. After entering the profile, click the Back button to change back to the Overview  Signal
flow dialog level.
Related topics:
Touch probe detection
Operating mode change with profile number
Positioning
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Commissioning of the "Table positioning" technology application
Lenze setting
Value Unit
absolute
(shortest way)t
360.0000 unit
360.0000 unit/s
720.0000 unit/s
720.0000 unit/s
0.000 s
0.0000 unit/s
0
0
TP-DigIn3
( 343)
( 519)
L
8400 HighLine C | Reference manual
Info
Selection of the way in which positioning is to be carried
out.
Positioning modes ( 526)
Target position or distance to be traversed.
Maximum speed at which the target is to be
approached.
2
Stipulation of the change in speed at which maximum
acceleration is to take place.
2
Stipulation of the change in speed at which maximum
deceleration to a standstill is to take place.
Due to stipulation of an S-ramp time for a profile, the
profile is executed with S-shaped ramps, i.e.
acceleration and braking processes are initiated
smoothly in order to reduce jerk and thus the stress on
the drive components.
This specifies the speed at which the drive is to start the
next profile after reaching the target position.
Optional: Sequence profile for profile linkage /
following block control.
After execution of the profile (target position reached),
the set following (subsequent) profile is started
automatically. In this way, profile chains can be
stipulated without additional control processes.
Optional: Profile number of the profile (1 ... 15) that is to
be executed after a touch probe has been detected.
• If "0" is set, there will be no profile stepping through
touch probe.
• Only relevant for positioning modes with touch-
probe.
Optional: Selection of the signal source for touch probe
detection.
• Only relevant for positioning modes with touch-
probe.
( 472)
Commissioning
79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents