Parameter reference
Parameter list | C00979
C00979
Parameter | Name:
C00979 | Cosine phi
From version 10.00.00
Display of the cosϕ setpoint and actual value with energy-saving V/f characteristic control (VFCplusEco)
Display range
(min. value | unit | max. value)
-1.00
Subcodes
C00979/1
C00979/2
Read access
C00980
Parameter | Name:
C00980 | Output power
From version 10.00.00
Display parameter for an energy analysis in the prevailing application. From this, decisions can be deduced whether
a measure for energy optimisation is economic.
Display range
(min. value | unit | max. value)
0.000
Subcodes
C00980/1
C00980/2
Read access
C00981
Parameter | Name:
C00981 | Energy display
From version 10.00.00
Display parameter for an energy analysis in the prevailing application. From this, decisions can be deduced whether
a measure for energy optimisation is economic.
• The values are saved to the device by switching off the mains and cannot be reset.
Display range
(min. value | unit | max. value)
0.00
Subcodes
C00981/1
C00981/2
Read access
C00982
Parameter | Name:
C00982 | VFC-ECO: Voltage reduction ramp
From version 10.00.00
Voltage ramp for cancelling V-Sub with energy-saving V/f characteristic control (VFCplusEco)
Setting range
(min. value | unit | max. value)
0.1
Read access
908
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Write access
CINH
PLC STOP
kW
Write access
CINH
PLC STOP
kWh
21474836.47
Write access
CINH
PLC STOP
s
Write access
CINH
PLC STOP
L
1.00
Info
Cosine phi act
Cosine phi set
No transfer
COM
MOT
Scaling factor: 100
32.000
Info
Active output power
Apparent output power
No transfer
COM
MOT
Scaling factor: 1000
Info
Output energy in motor mode
Output energy in generator mode
No transfer
COM
MOT
Scaling factor: 100
Lenze setting
5.0 0.8 s
No transfer
COM
MOT
Scaling factor: 10
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: INTEGER_16
Index: 23596
= 5C2C
d
h
Data type: INTEGER_32
Index: 23595
= 5C2B
d
h
Data type: INTEGER_32
Index: 23594
= 5C2A
d
h
Data type: UNSIGNED_8
Index: 23593
= 5C29
d
h

Hide quick links: