Lenze L-force HighLine C 8400 Series Reference Manual page 934

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

8400 HighLine C | Reference manual
Parameter reference
Parameter list | C01130
C01130
Parameter | Name:
C01130 | LS_RetainData: Selection
From version 11.00.00
Setting range
(min. hex value | max. hex value)
0x0000
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Subcodes
C01130/1
C01130/2
C01130/3
C01130/4
Read access
C01131
Parameter | Name:
C01131 | LS_RetainData: 16Bit data
From version 11.00.00
Setting range
(min. value | unit | max. value)
0
Subcodes
C01131/1
C01131/2
C01131/3
C01131/4
Read access
934
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
= bit set)
wIn1
wIn2
wIn3
wIn4
dnIn1
dnIn2
dnIn3
dnIn4
bIn1
bIn2
bIn3
bIn4
Reserved
Reserved
Reserved
Reserved
Lenze setting
15
240
3840
4095
Write access
CINH
PLC STOP
Lenze setting
0
0
0
0
Write access
CINH
PLC STOP
L
0xFFFF
Info
LS_RetainData: Selection bSetRetain_1
LS_RetainData: Selection bSetRetain_2
LS_RetainData: Selection bSetRetain_3
LS_RetainData: Selection bLoadParams
No transfer
COM
MOT
65535
Info
LS_RetainData: wValue1
LS_RetainData: wValue2
LS_RetainData: wValue3
LS_RetainData: wValue4
No transfer
COM
MOT
Scaling factor: 1
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: UNSIGNED_16
Index: 23445
= 5B95
d
h
Data type: UNSIGNED_16
Index: 23444
= 5B94
d
h

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents