8.4.4

Target position monitoring (status "drive in target")

The target position monitoring detects whether the drive has reached the target.
Note!
• The target position detection is active with the following operating
modes/functions:
– Operating mode "Positioning": Absolute and relative positioning mode
– Operating mode "Homing": After approaching the starting position via
– Operating mode
• The target position monitoring is active until the operating mode changes or
a new travel command influences the setpoint.
Short overview of the parameters for target position monitoring:
Parameter
C01244/1
C01245/1
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
start profile (if start profile has been selected)
"Manual
limit positions are approached
Info
MCK: Dwell time - target position
• For considering mechanical transient
phenomenons of the tool when the target
position is reached.
MCK: Window target position
• Symmetrical window around the target position.
L
8400 HighLine C | Reference manual
Basic drive functions (MCK)
jog": When the breakpoints and the software
Basic settings
Lenze setting
Value Unit
100 ms
1.0000 units