Lenze L-force HighLine C 8400 Series Reference Manual page 369

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

Identifier
bDriveFail
bDriveReady
bCInhActive
bQSPIsActive
bSpeedCcw
bSpeedActCompare
bOverLoadActive
bUnderLoadActive
bImaxActive
bSpeedSetReached
bSpeedActEqSet
nMotorCurrent_a
nMotorSpeedSet_a
nMotorSpeedAct_a
nMotorTorqueAct_a
nDCVoltage_a
nMotorVoltage_a
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Value/meaning
Data type
TRUE Drive controller in error status.
• "Fault" device status is active.
BOOL
TRUE Controller is ready for operation.
• "SwitchedOn" device status is active.
BOOL
• The drive is in this device status if the DC bus voltage is applied
and the controller is still inhibited by the user (controller inhibit).
TRUE Controller inhibit is active.
BOOL
TRUE Quick stop is active.
BOOL
Current direction of rotation
BOOL
FALSE Direction of rotation to the right (Cw)
TRUE Direction of rotation to the left (Ccw)
Result of the speed comparison
BOOL
TRUE During open-loop operation:
Speed setpoint < Comparison value (C00024)
During closed-loop operation:
Actual speed value < Comparison value (C00024)
In preparation (output is not interconnected on the application level)
BOOL
In preparation (output is not interconnected on the application level)
BOOL
"Current setpoint inside the limitation" status signal
BOOL
TRUE The current setpoint is internally limited (the drive controller
operates at the maximum current limit).
Status signal "setpoint = 0"
BOOL
TRUE Speed setpoint from the ramp function generator = 0
TRUE Actual speed value = speed setpoint
BOOL
Current stator current/effective motor current
• Scaling: 16384 ≡ 100 % I
INT
Speed setpoint
• Scaling: 16384 ≡ 100 % reference speed (C00011)
INT
Actual speed value
• Scaling: 16384 ≡ 100 % reference speed (C00011)
INT
Actual torque
• In the "VFC (+encoder)" operating mode of the motor control, this value is
INT
determined from the current motor current and corresponds to the actual torque
only by approximation.
• Scaling: 16384 ≡ 100 % M
Actual DC-bus voltage
• Scaling: 16384 ≡ 1000 V
INT
Current motor voltage/inverter output voltage
• Scaling: 16384 ≡ 1000 V
INT
L
8400 HighLine C | Reference manual
Technology applications
TA "Actuating drive speed"
(C00022)
max_mot
(C00057)
max
369