Advertisement

C00725
Parameter | Name:
C00725 | Current switching frequency
Display of the current switching frequency
• In
C00018
you can choose between a drive-optimised setting for good smooth-running characteristics and an
inverter loss-optimised setting (min. Pv).
• Both possibilities offer fixed and variable switching frequencies.
• When a variable switching frequency is selected in C00018, the switching frequency may change as a function
of the load and rotational frequency.
Selection list
(read only)
Read access
C00726
Parameter | Name:
C00726 | Current limit values
This code is for device-internal use only and must not be written to by the user!
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1 4 kHz var./drive-optimised
2 8 kHz var./drive-optimised
3 16 kHz var./drive-optimised
5 2 kHz constant/drive-optimised
6 4 kHz constant/drive-optimised
7 8 kHz constant/drive-optimised
8 16 kHz constant/drive-optimised
11 4 kHz var./min. Pv
12 8 kHz var./min. Pv
13 16 kHz var./min. Pv
14 Reserved
15 2 kHz constant/min. Pv
16 4 kHz constant/min. Pv
17 8 kHz constant/min. Pv
18 16 kHz constant/min. Pv
21 8 kHz var./drive-opt./4 kHz min
22 16 kHz var./drive-opt./4 kHz min
23 16 kHz var./drive-opt./8 kHz min
31 8 kHz var./min. Pv/4 kHz min
32 16 kHz var./min. Pv/4 kHz min
33 16 kHz var./min. Pv/8 kHz min
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
No transfer
COM
MOT
Scaling factor: 1
Parameter reference
Parameter list | C00725
Data type: UNSIGNED_8
Index: 23850
= 5D2A
d
h
Data type: UNSIGNED_8
Index: 23849
= 5D29
d
h
843