Commissioning - Lenze 9350 Series Operating Instructions Manual

Braking unit
Hide thumbs Also See for 9350 Series:
Table of Contents

Advertisement

Available languages

Available languages

7

Commissioning

(
Stop!
Before initial switch−on, check
ƒ
ƒ
ƒ
Operating status display
The two LEDs on the braking unit display the operating status:
LED display
Green
Yellow
Off
Off
On
Off
On
On
Operating notes
)
Note!
The total braking time of a drive is increased if the power that is
regenerated is greater than the peak braking power of the brake
resistor assigned.
In this case the controller sets pulse inhibit and reports
"overvoltage". Remedy to ensure continuous deceleration with a
steady braking torque:
ƒ
ƒ
EDBMB935X DE/EN/FR 11.0
whether the terminals +U
– If +U
and −U
are inverted, braking units and all components
G
G
connected can be destroyed.
the switching thresholds of the braking unit(s) are set to the same
values for the entire drive system via switches S1 and S2
– Setting the switching thresholds: see chapter 6.6.
the braking units are configured correctly via S3 if braking units
are connected in parallel.
– The 1. braking unit as master (S3 = OFF).
– All further braking units as slaves (S3 = ON).
Operating status
Braking unit without voltage, not ready for operation.
Braking unit is supplied with voltage and is ready for operation.
Braking unit in braking operation, energy is converted within the brake
resistor.
If the braking power is small, the braking times are short, or, during operation
with a switching threshold of 375 V, the luminosity of the yellow LED is very
low.
Increase deceleration time T
If permissible, use a low−resistance brake resistor.
l
Commissioning
and −U
are connected correctly.
G
G
or the QSP ramp at the controller, or
if
7