8400 HighLine C | Reference manual
Parameter reference
Parameter list | C00020
C00020
Parameter | Name:
C00020 | AIN2: Characteristic
From version 04.00.00
Setting range
(min. value | unit | max. value)
0.00
Subcodes
C00020/1
C00020/2
C00020/3
C00020/4
C00020/5
C00020/6
C00020/7
C00020/8
Read access
C00021
Parameter | Name:
C00021 | Slip comp.
Slip compensation for V/f characteristic control (VFCplus) and sensorless vector control (SLVC)
• A higher slip compensation results in a higher increase in frequency and voltage when the machine is under load.
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range
(min. value | unit | max. value)
-100.00
Read access
C00022
Parameter | Name:
C00022 | Imax in motor mode
Maximum current in motor mode for all motor control modes
Setting range
(min. value | unit | max. value)
0.00
Read access
C00023
Parameter | Name:
C00023 | Imax in generator mode
Maximum current in generator mode for all motor control modes
• 100 % ≡ Imax in motor mode (C00022)
Setting range
(min. value | unit | max. value)
0.00
Read access
720
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
%
Lenze setting
0.00 %
0.00 %
0.00 %
0.00 %
100.00 %
100.00 %
100.00 %
100.00 %
Write access
CINH
PLC STOP
Motor control
(MCTRL):
%
Write access
CINH
PLC STOP
A
Write access
CINH
PLC STOP
%
Write access
CINH
PLC STOP
L
Analog
terminals:
199.99
Info
AIN2: (+y0) = min
AIN2: (+x0) = Dead band
AIN2: (-y0) = (-min)
AIN2: (-x0) = (-Dead band)
AIN2: (+ymax)
AIN2: (+xmax)
AIN2: (-ymax)
AIN2: (-xmax)
No transfer
COM
MOT
Scaling factor: 100
Optimising the operational performance by slip compensation
Lenze setting
100.00 2.67 %
No transfer
COM
MOT
Scaling factor: 100
Lenze setting
655.35 47.00 A
No transfer
COM
MOT
Scaling factor: 100
Lenze setting
100.00 100.00 %
No transfer
COM
MOT
Scaling factor: 100
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Data type: INTEGER_16
Index: 24555
= 5FEB
d
Signal adaptation via characteristic
Data type: INTEGER_16
Index: 24554
= 5FEA
d
Data type: UNSIGNED_16
Index: 24553
= 5FE9
d
Data type: INTEGER_16
Index: 24552
= 5FE8
d
h
h
h
h