Set Machine Parameters - Lenze L-force HighLine C 8400 Series Reference Manual

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

3.7.4.1

Set machine parameters

Note!
Setting the machine parameters is a basic prerequisite for the operating modes
"Homing",
The more precisely the machine parameters are set, the better the results of
positioning!
Detailed information on the machine parameters is provided in chapter "Basic
drive functions" in subchapter
1. Go to the right side of the Application parameter tab and click the Machine parameter
button to change to the Overview  Machine parameter dialog level:
2. Set the machine parameters according to the system constellation at hand.
Parameter
Mounting direction: Motor
(C01206/1)
Numerator
(C01202/1)
Denominator
(C01202/2)
Mounting direction: Position
encoder
(C01206/2)
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Commissioning of the "Table positioning" technology application
"Manual
jog" and "Positioning".
"Machine
Lenze setting
Value Unit
not inverted
1
1
not inverted
L
8400 HighLine C | Reference manual
parameters".
( 475)
Info
Inversion if motor mounting is mirrored.
Gearbox factor - motor
• Entry of the gearbox factor as
numerator/denominator ratio (numerator = motor
speed and denominator = output speed of gearbox)
or from the number of teeth of the gearbox
arrangement.
Inversion if position encoder mounting is mirrored.
Commissioning
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L-force highline e84avhc series

Table of Contents