8400 HighLine C | Reference manual
Motor control (MCTRL)
Braking operation/brake energy management
Tip!
In C00175, a ramp function generator stop (FB L_NSet_1) can be set for instances
when the brake resistor is controlled. This prevents overvoltage deactivation in the
case of short deceleration times.
Selecting the response to an increase of the DC-bus voltage
Proceed as follows to open the dialog for parameterising the brake energy

management:

1. »Engineer« Go to the Project view and select the 8400 HighLine controller.
2. Go to Workspace and change to the Application parameters tab.
3. Go to the Overview dialog level and click the "basic functions" button.
4. Go to the Overview  basic functions dialog box and click the Brake energy
management button.
Short overview of the relevant parameters:
Parameter
C00173
C00175
Highlighted in grey = display parameter
280
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Info
Mains voltage
Brake energy management
L
( 282)
Lenze setting
Value Unit
3ph 400 V / 1ph 230 V
R_Brake (brake resistance)
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011