Setting Parameters (Short Overview) - Lenze L-force HighLine C 8400 Series Reference Manual

Inverter drives
Hide thumbs Also See for L-force HighLine C 8400 Series:
Table of Contents

Advertisement

Status word
7.4.5

Setting parameters (short overview)

Parameter
C00011
C00012
C00013
C00105
C00039/1
C00039/2
C00039/3
C00039/4...15
C00101/1...15
C00103/1...15
C00105
C00106
C00107
C00134
C00182
C00190
C00220
C00221
C00241
C00488/1
C00488/2
C00488/3
C00488/4
C00488/5
C00488/6
C00632/1
C00632/2
C00632/3
C00633/1
C00633/2
C00633/3
C00635
C00636
C00670
C00671
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Name
Bit 13 Trouble
Bit 14 JogCtrlInputSel1
Bit 15 JogCtrlInputSel2
Info
Appl.: Reference speed
Accel. time - main setpoint
Decel. time - main setpoint
Decel. time - quick stop
Fixed setpoint 1
Fixed setpoint 2
Fixed setpoint 3
Fixed setpoint 4 ... 15
Add. accel. time 1 ... 15
Add. decel. time 1 ... 15
Decel. time - quick stop
Auto-DCB: Hold time
DCB braking: Hold time
L_NSet_1: Ramp smoothing
L_NSet_1: S-ramp time PT1
L_NSet_1: Setpoint arithmetic
L_NSet_1: Acceleration time - add. setpoint
L_NSet_1: Deceleration time - add. setpoint
L_NSet_1: Hyst. NSet reached
InputSens.SlowDown1
InputSens.Stop1
InputSens.SlowDown2
InputSens.Stop2
InputSens.SlowDown3
InputSens.Stop3
L_NSet_1: Blocking speed 1 max
L_NSet_1: Blocking speed 2 max
L_NSet_1: Blocking speed 3 max
L_NSet_1: Blocking speed 1 min
L_NSet_1: Blocking speed 2 min
L_NSet_1: Blocking speed 3 min
L_NSet_1: nMaxLimit
L_NSet_1: nMinLimit
L_OffsetGainP_1: Gain
L_OffsetGainP_2: Gain
L
8400 HighLine C | Reference manual
TA "Switch-off positioning"
Status
1 ≡ Controller is in the "Trouble" device status
• E.g. if an overvoltage has occurred.
Binary coded selection of the switch-off position 1 ... 3
• Bits 5 and 6 of the control word.
Technology applications
Lenze setting
Value Unit
1500 rpm
2.000 s
2.000 s
2.000 s
40.00 %
60.00 %
80.00 %
0.00 %
0.000 s
0.000 s
2.000 s
0.500 s
999.000 s
0: Off
20.00 s
0: Out = Set
0.000 s
0.000 s
0.50 %
0: Level
0: Level
0: Level
0: Level
0: Level
0: Level
0.00 %
0.00 %
0.00 %
0.00 %
0.00 %
0.00 %
199.99 %
-199.99 %
1.0000
1.0000
439

Hide quick links: