8400 HighLine C | Reference manual
Basic drive functions (MCK)
Manual jog
8.7.1.4
Time-based start of second speed
If this function has been activated by means of bit 1 in
has been set in C01235/1, an automatic change-over to manual jog speed 2 takes place
when the manual jog function is activated and after the waiting time has expired.
When the waiting time is set = 0 s, the automatic change-over is deactivated.
Time-based start deactivated
(C01230
- bit 1 = 0; Lenze setting)
n
ManJogPos
TRUE
FALSE
C01231/1: Manual jog: Speed 1
C01231/2: Manual jog: Speed 2
C01235/1: Waiting time 2nd speed (Lenze setting: 5 s)
[8-23] Time-based start of second speed
Tip!
By leaving the corresponding button for manual jog pressed down for longer than
the waiting time and parameterising manual jog speed 2 so that it is higher than
manual jog speed 1, you can enable longer distances to be travelled by means of
manual jogging with this function.
514
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
t
t
L
C01230
and a waiting time > "0 s"
Time-based start activated
(C01230
- bit 1 = 1)
n
ManJogPos
TRUE
FALSE
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
t
t