C00138
Parameter | Name:
C00138 | Internal control signals
Bit coded display of internal control signals of different sources
Display area
(min. hex value | max. hex value)
0x0000
Value is bit-coded:
Bit 0 Reserved
Bit 1 DisableVoltage
Bit 2 SetQuickStop
Bit 3 EnableOperation
Bit 4 InitFinishedOK
Bit 5 ModeSpecific_2
Bit 6 ModeSpecific_3
Bit 7 ResetFault
Bit 8 SetHalt
Bit 9 FirmwareUpdate
Bit 10 MotorIdent
Bit 11 SetMessage
Bit 12 SetIMP
Bit 13 SetSystemFail
Bit 14 SetFail
Bit 15 SetFailQSP
Subcodes
C00138/1
C00138/2
C00138/3
Read access
C00142
Parameter | Name:
C00142 | Auto-start option
Starting performance of the controller after mains connection, undervoltage, loading of the Lenze setting as well as
a reset of "Trouble" or "Fault" can be parameterised individually.
Setting range
(min. hex value | max. hex value)
0x00
Value is bit-coded: (
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Read access
Firmware ≤ 11.00 - DMS 6.0 EN - 10/2011
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Write access
CINH
PLC STOP
= bit set)
Inhibit at power-on
Inhibit at trouble
Inhibit at fault
Inhibit at undervoltage
Inhibit at Lenze setting
Reserved
Reserved
Reserved
Write access
CINH
PLC STOP
L
8400 HighLine C | Reference manual
0xFFFF
Info
SYS control signals
MCK control signals
FWM control signals
No transfer
COM
MOT
Automatic restart after mains connection/fault...
Lenze setting
0xFF 0x19 (decimal: 25)
Info
From version 06.00.00
No transfer
COM
MOT
Parameter reference
Parameter list | C00138
Data type: UNSIGNED_16
Index: 24437
= 5F75
d
h
Data type: UNSIGNED_8
Index: 24433
= 5F71
d
h